Radiometry, Infrared Systems, Tracking

Use of gadolinium oxyorthosilicate scintillators in x-ray radiometers

[+] Author Affiliations
V. D. Ryzhikov, B. V. Grinev, E. N. Pirogov, G. M. Onyshchenko, A. I. Ivanov, V. G. Bondar, K. A. Katrunov

STC Institute for Single Crystals, 60 Lenin Avenue, Kharkov, Ukraine, 61001 E-mail: stcri@isc.kharkov.com

S. A. Kostyukevich

Institute of Semiconductor Physics, 41 Nauky Avenue, Kiev, Ukraine, 03028 E-mail: info@spie.org.ua

Opt. Eng. 44(1), 016403 (Dec. 21, 2004). doi:10.1117/1.1829713
History: Received Oct. 7, 2003; Revised Jan. 14, 2004; Accepted Jul. 15, 2004; Dec. 21, 2004; Online December 21, 2004
Text Size: A A A

In radiometers for the x-ray range (E10 to 100 keV) the use of oxide scintillators based on gadolinium oxyorthosilicate (GSO) has many advantages over alkali halide scintillators, e.g., NaI(Tl). The shape of spectra obtained with GSO and cadmium tungstate (CWO) scintillators has certain features that substantially increase the sensitivity of radiometers that use the energy windows algorithm and allowed us to design a detector for simultaneous detection of low-energy γ radiation of 241Am (59.6 keV) and 137Cs (≈33 keV). These features of oxide scintillators have allowed a substantial increase in sensitivity of the selective radiometer RK-AG-02M, which is designed for measurements of 241Am activity in soil samples against the background of 137Cs. The results obtained in this work show that the use of GSO and (in several cases) CWO scintillators in instruments involving x-ray range of radiation (e.g., thickness meters, radiometers) is a very promising field for their application. To ensure efficient use of GSO, sufficiently high optical luminescence, scintillation, and other functional characteristics of this scintillator are required, which can be improved by thermal treatment. In this connection, results are presented on thermal treatment of GSO:Ce crystals. In RK-AG-02M we are using a scintillation unit based on a GSO scintillator. To increase the measurement accuracy in the bulk density range of 0.6 to 2.5 g/cm3, a correcting function has been obtained for the radiometer sensitivity. © 2005 Society of Photo-Optical Instrumentation Engineers.

© 2005 Society of Photo-Optical Instrumentation Engineers

Citation

V. D. Ryzhikov ; B. V. Grinev ; E. N. Pirogov ; G. M. Onyshchenko ; A. I. Ivanov, et al.
"Use of gadolinium oxyorthosilicate scintillators in x-ray radiometers", Opt. Eng. 44(1), 016403 (Dec. 21, 2004). ; http://dx.doi.org/10.1117/1.1829713


Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging & repositioning the boxes below.

Related Book Chapters

Topic Collections

Advertisement
  • Don't have an account?
  • Subscribe to the SPIE Digital Library
  • Create a FREE account to sign up for Digital Library content alerts and gain access to institutional subscriptions remotely.
Access This Article
Sign in or Create a personal account to Buy this article ($20 for members, $25 for non-members).
Access This Proceeding
Sign in or Create a personal account to Buy this article ($15 for members, $18 for non-members).
Access This Chapter

Access to SPIE eBooks is limited to subscribing institutions and is not available as part of a personal subscription. Print or electronic versions of individual SPIE books may be purchased via SPIE.org.