Paper
14 November 1996 Acoustic emission monitoring for inspection of seam-welded hot reheat piping in fossil power plants
John M. Rodgers, Bryan C. Morgan, Richard M. Tilley
Author Affiliations +
Abstract
Although failure of the seam weld on reheat steam piping has been an infrequent occurrence, such failure is still a major safety concern for fossil plant operations. EPRI has provided guidelines for a piping management program base don periodic inspection. More recently, EPRI has also sponsored research to develop inspection techniques to both improve the quality and reduce the cost of piping inspections. Foremost in this research has been the use of acoustic emission (AE) techniques to detect crack damage in seam welds. AE has the substantial cost advantages of both allowing inspection without full removal of the thermal insulation on the reheat piping and making short-re- inspection intervals practical. This paper reviews the EPRI guidelines for performing an AE inspection on seam-welded hot reheat piping.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
John M. Rodgers, Bryan C. Morgan, and Richard M. Tilley "Acoustic emission monitoring for inspection of seam-welded hot reheat piping in fossil power plants", Proc. SPIE 2947, Nondestructive Evaluation of Utilities and Pipelines, (14 November 1996); https://doi.org/10.1117/12.259159
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Inspection

Waveguides

Signal detection

Acoustic emission

Signal processing

Nondestructive evaluation

Back to Top