Paper
21 March 2007 Easy and stable bronchoscope camera calibration technique for bronchoscope navigation system
Kazuyoshi Ishitani, Deguchi Daisuke, Takayuki Kitasaka, Kensaku Mori, Yasuhito Suenaga, Hirotsugu Takabatake, Masaki Mori, Hiroshi Natori
Author Affiliations +
Abstract
This paper presents an easy and stable bronchoscope camera calibration technique for bronchoscope navigation system. A bronchoscope navigation system is strongly expected to be developed to make bronchoscopic examinations safer and more effective. In a bronchoscope navigation system, virtual bronchoscopic images are generated from a 3D CT image taken prior to an examination to register a patient's body and his/her CT image. It is absolutely indispensable to know correct intrinsic camera parameters such as focal length, aspect ratio, and the projection center of the camera for the generation of virtual bronchoscopic images. In the case of a bronchoscope, however, it is very complicated to obtain these camera parameters by calibration techniques applied to conventional cameras, since a bronchoscope camera has heavy barrel-type lens distortion. Also image resolution is quite low. Therefore, we propose an easy and stable bronchoscope camera calibration technique that does not require any special devices. In this method, a planar calibration pattern is captured at many different angles by moving the bronchoscope camera freely. Then we automatically detect feature points for camera calibration from captured images. Finally, intrinsic camera parameters are estimated from these extracted feature points by applying Zhang's calibration technique. We applied the proposed method to a conventional bronchoscope camera. The experimental results showed that reprojection error using estimated camera parameters was about 0.7 pixels. Also stable estimation was achieved by the proposed method.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kazuyoshi Ishitani, Deguchi Daisuke, Takayuki Kitasaka, Kensaku Mori, Yasuhito Suenaga, Hirotsugu Takabatake, Masaki Mori, and Hiroshi Natori "Easy and stable bronchoscope camera calibration technique for bronchoscope navigation system", Proc. SPIE 6509, Medical Imaging 2007: Visualization and Image-Guided Procedures, 65091I (21 March 2007); https://doi.org/10.1117/12.710398
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cameras

Calibration

Sensors

Imaging systems

Feature extraction

Navigation systems

Distortion