Paper
22 February 2008 Detection of TNT in acetone using Raman spectroscopic signature
Author Affiliations +
Proceedings Volume 6622, International Symposium on Photoelectronic Detection and Imaging 2007: Laser, Ultraviolet, and Terahertz Technology; 662219 (2008) https://doi.org/10.1117/12.790827
Event: International Symposium on Photoelectronic Detection and Imaging: Technology and Applications 2007, 2007, Beijing, China
Abstract
The detection of explosive agents is becoming more important and receiving much greater emphasis for homeland defense. Raman spectroscopy is a well established tool for vibration spectroscopic analysis and can be applied to the field of explosives identification and detection. The major bands of the Raman spectroscopy of industrial TNT (Trinitrotoluene, CH3C6H2(NO2)3) are analyzed and seven prominent peaks, that is 1616.9cm-1 (C=C aromatic stretching vibration), 1533.9cm-1 (NO2 asymmetric stretching vibration), 1360.1cm-1 (NO2 symmetric stretching vibration ), 1210.5cm-1 (C6H2-C vibration), 822.9cm-1 (nitro-group scissoring mode), 792.3cm-1 (C-H out-of-plane bend), and 326.7cm-1 (framework distortion mode) are used to identify the TNT. The Raman spectroscopes of TNT solved in acetone at different mass ratios are studied, and the TNT in the solution can be detected correctly according the relative distance, intensity, and peak area of the seven peaks. The TNT prominent peaks appear clearly in high level solution (the mass ration of TNT and acetone is more than 1:10). With the decrease of TNT concentration in solution, the signature of TNT becomes more and more weak. The low detection limit of TNT is limited by the noise of the instrument (NXR FT-Raman accessory module with Nicolet 5700 FT-IR spectrometer is used for our experiments. The low detection limit in our experiments is mass ratio 1:200, which is about 4mg/mL). The prominent peak heights are discussed in consideration of the TNT concentration. Taking one of the acetone's peaks (1716.9cm-1) as the internal standard line, the relative height of the prominent TNT peaks is almost proportional to the concentration of the TNT in the solution. A fitting curve for the relations of prominent peak height according to the concentration is proposed with multinomial fitting method, which can be used to analyze the concentration of TNT more accurately.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xiaofeng Wang, Shengli Chang, Jiankun Yang, Jichun Tan, Honghui Jia, Hongwei Yin, Xiujian Li, and Guanliang Peng "Detection of TNT in acetone using Raman spectroscopic signature", Proc. SPIE 6622, International Symposium on Photoelectronic Detection and Imaging 2007: Laser, Ultraviolet, and Terahertz Technology, 662219 (22 February 2008); https://doi.org/10.1117/12.790827
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Raman spectroscopy

Spectroscopy

Explosives

Analytical research

Explosives detection

Defense technologies

Molecules

RELATED CONTENT


Back to Top