Paper
27 November 2007 Optical multichannel analyzer constructed with 4400 system for glass surface and thin film measurement
Zhengtian Gu, Ren Ye, Zhenyuan Wang, Peihui Liang
Author Affiliations +
Proceedings Volume 6723, 3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment; 67231M (2007) https://doi.org/10.1117/12.783187
Event: 3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Large Mirrors and Telescopes, 2007, Chengdu, China
Abstract
A new scheme of optical multichannel analyzer is developed based on Model 4400 Signal Detection and Analysis System. The scheme consists of an optical signal source, a photodiode array and Model 4400 Signal Detection and Analysis System. The signal source provides varies light intensity distribution from optical system. The photodiode array transforms spatial distribution of light intensity into time dependence of electric current intensity. Model 4400 Signal Detection and Analysis System carries out signal processing and analysis through boxcar, keyboard control and advanced microprocessor. With this scheme, the spatial distribution of laser light-intensity was described and the relevant parameters such as beam waist radius of Gaussian distribution were obtained. Further, the optical parameters of the plane glass surface and PMTES thin films were obtained by p-polarized reflectance method. By measuring the angle distribution of reflectance ratio and fitting the results with theoretical data, the optical parameters can be obtained easily. Experimental results indicate that the refractive index and extinction coefficient of glass surface layers decrease exponentially with the thickness of glass layer. Also the optical parameters of PMTES films with the presented scheme have been measured, and the experimental results coincide well with theoretical simulation only if the glass surface layers are considered. Due to the introduction of digital averaging technique in 4400 System, the sampling signals with higher signal-to-noise ratio are acquired, and the presented scheme has higher measurement precision, which is very suitable to temporal-spatial transform and analysis of optical field and precise measurement of surface and film system.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhengtian Gu, Ren Ye, Zhenyuan Wang, and Peihui Liang "Optical multichannel analyzer constructed with 4400 system for glass surface and thin film measurement", Proc. SPIE 6723, 3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, 67231M (27 November 2007); https://doi.org/10.1117/12.783187
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Glasses

Signal detection

Computing systems

Photodiodes

Analytical research

Reflectivity

Thin films

Back to Top