18 March 2008 Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory
Author Affiliations +
Abstract
In this paper, we present shift-invariant filtered backprojection (FBP) cone-beam image reconstruction algorithms for a cone-beam CT system based on a clinical C-arm gantry. The source trajectory consists of two concentric arcs which is complete in the sense that the Tuy data sufficiency condition is satisfied. This scanning geometry is referred to here as a CC geometry (each arc is shaped like the letter "C"). The challenge for image reconstruction for the CC geometry is that the image volume is not well populated by the familiar doubly measured (DM) lines. Thus, the well-known DM-line based image reconstruction schemes are not appropriate for the CC geometry. Our starting point is a general reconstruction formula developed by Pack and Noo which is not dependent on the existence of DM-lines. For a specific scanning geometry, the filtering lines must be carefully selected to satisfy the Pack-Noo condition for mathematically exact reconstruction. The new points in this paper are summarized here. (1) A mathematically exact cone-beam reconstruction algorithm was formulated for the CC geometry by utilizing the Pack-Noo image reconstruction scheme. One drawback of the developed exact algorithm is that it does not solve the long-object problem. (2) We developed an approximate image reconstruction algorithm by deforming the filtering lines so that the long object problem is solved while the reconstruction accuracy is maintained. (3) In addition to numerical phantom experiments to validate the developed image reconstruction algorithms, we also validate our algorithms using physical phantom experiments on a clinical C-arm system.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Tingliang Zhuang, Joseph Zambelli, Brian Nett, Shuai Leng, and Guang-Hong Chen "Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory", Proc. SPIE 6913, Medical Imaging 2008: Physics of Medical Imaging, 691321 (18 March 2008); https://doi.org/10.1117/12.772390
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reconstruction algorithms

Algorithm development

Image restoration

Sensors

Image filtering

Data acquisition

Detection and tracking algorithms

Back to Top