Paper
2 August 2010 Dual frequency sweeping interferometry for absolute distance metrology at long ranges: implementation and performance
Author Affiliations +
Abstract
Frequency sweeping interferometry (FSI) is a technique where absolute distance measurements are made without ambiguity, by using synthetic wavelengths resulting from a frequency sweep. In FSI, the measurement uncertainty increases with the distance, as consequence of the propagation of the uncertainty in the synthetic wavelength measurement. For long ranges, this component of the uncertainty budget is one of the major drawbacks of the technique. To overcome this problem, we introduced the concept of the dual FSI mode, where the measurement process for longer ranges is reduced to the close range case, by limiting the Optical Path Diference in the interferometer. This was achieved by increasing the reference arm with a long reference fiber, and using a second ancillary interferometer to calibrate continuously the fiber length and compensate temperature variations. In the context of the ESA PROBA3 space mission (coronagraph and demonstration of metrology for free-flying formation), we implemented a FSI sensor composed of a mode-hop free frequency sweep external cavity diode laser, a high finesse Fabry-Perot interferometer (to measure accurately the frequency sweep range) and a dual measurement system. This dual FSI concept, presented in San Diego in 2008, was now implemented and fully tested in view of the PROBA3 mission. Accuracies smaller than 32 μm for a measurement range from 51 m to 61 m were achieved using a reference fiber with 71 m, maintaining the reduced complexity inherent to FSI technique, a mandatory condition for space applications. Implementation issues and performance results are also discussed in this paper.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Alexandre Cabral, Manuel Abreu, José M. Rebordão, and Vitor Oliveira "Dual frequency sweeping interferometry for absolute distance metrology at long ranges: implementation and performance", Proc. SPIE 7790, Interferometry XV: Techniques and Analysis, 779005 (2 August 2010); https://doi.org/10.1117/12.859120
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Interferometers

Distance measurement

Metrology

Sensors

Interferometry

Temperature metrology

Back to Top