Paper
23 August 2013 Design of an optical system with large depth of field using in the micro-assembly
Rong Li, Jun Chang, Zhi-jing Zhang, Xin Ye, Hai-jing Zheng
Author Affiliations +
Proceedings Volume 8911, International Symposium on Photoelectronic Detection and Imaging 2013: Micro/Nano Optical Imaging Technologies and Applications; 89110N (2013) https://doi.org/10.1117/12.2034559
Event: ISPDI 2013 - Fifth International Symposium on Photoelectronic Detection and Imaging, 2013, Beijing, China
Abstract
Micro system currently is the mainstream of application and demand of the field of micro fabrication of civilian and national defense. Compared with the macro assembly, the requirements on location accuracy of the micro-assembly system are much higher. Usually the dimensions of the components of the micro-assembly are mostly between a few microns to several hundred microns. The general assembly precision requires for the sub-micron level. Micro system assembly is the bottleneck of micro fabrication currently. The optical stereo microscope used in the field of micro assembly technology can achieve high-resolution imaging, but the depth of field of the optical imaging system is too small. Thus it’s not conducive to the three-dimensional observation process of the micro-assembly. This paper summarizes the development of micro system assembly at home and abroad firstly. Based on the study of the core features of the technology, a program is proposed which uses wave front coding technology to increase the depth of field of the optical imaging system. In the wave front coding technology, by combining traditional optical design with digital image processing creatively, the depth of field can be greatly increased, moreover, all defocus-related aberrations, such as spherical aberration, chromatic aberration, astigmatism, Ptzvel(field) curvature, distortion, and other defocus induced by the error of assembling and temperature change, can be corrected or minimized. In this paper, based on the study of theory, a set of optical microscopy imaging system is designed. This system is designed and optimized by optical design software CODE V and ZEMAX. At last, the imaging results of the traditional optical stereo microscope and the optical stereo microscope applied wave front coding technology are compared. The results show that: the method has a practical operability and the phase plate obtained by optimized has a good effect on improving the imaging quality and increasing the depth of field.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Rong Li, Jun Chang, Zhi-jing Zhang, Xin Ye, and Hai-jing Zheng "Design of an optical system with large depth of field using in the micro-assembly", Proc. SPIE 8911, International Symposium on Photoelectronic Detection and Imaging 2013: Micro/Nano Optical Imaging Technologies and Applications, 89110N (23 August 2013); https://doi.org/10.1117/12.2034559
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Microscopes

Optical design

Wavefronts

Imaging systems

Optical imaging

Zoom lenses

3D image processing

Back to Top