Paper
18 September 2014 Optomechanical design of near-null subaperture test system based on counter-rotating CGH plates
Author Affiliations +
Proceedings Volume 9282, 7th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment; 92820I (2014) https://doi.org/10.1117/12.2068330
Event: 7th International Symposium on Advanced Optical Manufacturing and Testing Technologies (AOMATT 2014), 2014, Harbin, China
Abstract
In off-axis subapertures of most convex aspheres, astigmatism and coma dominate the aberrations with approximately quadratic and linear increase as the off-axis distance increases. A pair of counter-rotating computer generated hologram (CGH) plates is proposed to generate variable amount of Zernike terms Z4 and Z6, correcting most of the astigmatism and coma for subapertures located at different positions on surfaces of various aspheric shapes. The residual subaperture aberrations are then reduced within the vertical range of measurement of the interferometer, which enables near-null test of aspheres flexibly. The alignment tolerances for the near-null optics are given with optomechanical analysis. Accordingly a novel design for mounting and aligning the CGH plates is proposed which employs three concentric rigid rings. The CGH plate is mounted in the inner ring which is supported by two couples of ball-end screws in connection with the middle ring. The CGH plate along with the inner ring is hence able to be translated in X-axis and tipped by adjusting the screws. Similarly the middle ring is able to be translated in Y-axis and tilted by another two couples of screws orthogonally arranged and connected to the outer ring. This design is featured by the large center-through hole, compact size and capability of four degrees-of-freedom alignment (lateral shift and tip-tilt). It reduces the height measured in the direction of optical axis as much as possible, which is particularly advantageous for near-null test of convex aspheres. The CGH mounts are then mounted on a pair of center-through tables realizing counter-rotation. Alignment of the interferometer, the CGHs, the tables and the test surface is also discussed with a reasonable layout of the whole test system. The interferometer and the near-null optics are translated by a three-axis stage while the test mirror is rotated and tilted by two rotary tables. Experimental results are finally given to show the near-null subaperture test capability of the system for a convex even asphere.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yepeng Li, Shanyong Chen, Bing Song, and Shengyi Li "Optomechanical design of near-null subaperture test system based on counter-rotating CGH plates", Proc. SPIE 9282, 7th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, 92820I (18 September 2014); https://doi.org/10.1117/12.2068330
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Computer generated holography

Interferometers

Aspheric lenses

Monochromatic aberrations

Mirrors

Aspheric optics

Optical alignment

RELATED CONTENT

The design method of CGH for testing the Ф404, F2...
Proceedings of SPIE (September 02 2014)
Interferometric cross test of a convex even asphere
Proceedings of SPIE (August 11 2015)
The method to reduce the spinal error in the aspheric...
Proceedings of SPIE (September 27 2016)
Modified alignment CGHs for aspheric surface test
Proceedings of SPIE (August 21 2009)
The off axis alignment of an asphere by a Fizeau...
Proceedings of SPIE (May 23 2011)

Back to Top