Paper
23 November 2015 Test station development for laser-induced optical damage performance of broadband multilayer dielectric coatings
K. R. P. Kafka, E. A. Chowdhury, R. A. Negres, C. J. Stolz, J. D. Bude, A. J. Bayramian, C. D. Marshall, T. M. Spinka, C. L. Haefner
Author Affiliations +
Abstract
Laser-induced damage threshold (LIDT) testing was performed on commercially-available multilayer dielectric coatings to qualify for use in the High Repetition-Rate Advanced Petawatt Laser System (HAPLS) for Extreme Light Infrastructure Beamlines. Various tests were performed with uncompressed pulses (150 ps) from a 780 nm-centered Ti:Sapphire regenerative ampliflier, and the raster scan method was used to determine the best-performing coatings. Performance varied from 2–8 J/cm2 across samples from 6 different manufacturers.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
K. R. P. Kafka, E. A. Chowdhury, R. A. Negres, C. J. Stolz, J. D. Bude, A. J. Bayramian, C. D. Marshall, T. M. Spinka, and C. L. Haefner "Test station development for laser-induced optical damage performance of broadband multilayer dielectric coatings", Proc. SPIE 9632, Laser-Induced Damage in Optical Materials: 2015, 96321C (23 November 2015); https://doi.org/10.1117/12.2195786
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Raster graphics

Optical coatings

Laser development

Laser induced damage

Dielectrics

Cameras

Manufacturing