Paper
27 November 1984 The Use Of Ronchi Rulings For High Precision, Two-Dimensional Galvo Deflection Systems
D. J. Bernays
Author Affiliations +
Abstract
Ronchi rulings can serve as low cost, high precision position references in galvo-based, actively-stabilized laser deflection systems. An overview of beam position sensing principles is presented, including a comparison of the design trade offs between monotonic and periodic position sensors. Next, methods are described to use a Ronchi ruling as a mask to define a series of identical locations on a media. Each location is the gap between two bars of the Ronchi ruling. By focusing the beam onto the grating, and introducing a high frequency, low amplitude dither in the beam position, a position signal can be generated which is zero when the beam is centered between two grating bars. This signal is suitable for use in a position stabilization loop which keeps the beam centered at the particular location. A method of using a pair of quadrature signals (including the dither position signal) is described in which the beam position can be tracked while scanning across many locations. A dual mode demonstration system is described which accesses any of 63 positions with a settling time less than two milliseconds. The spot size is 50 microns, resolution 1 micron and drift is not measurable. Techniques for extending the one-dimensional deflection to two-dimensional (x-y) operation are presented.
© (1984) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
D. J. Bernays "The Use Of Ronchi Rulings For High Precision, Two-Dimensional Galvo Deflection Systems", Proc. SPIE 0498, Laser Scanning and Recording, (27 November 1984); https://doi.org/10.1117/12.944547
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications and 2 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Photoemission spectroscopy

Sensors

Ronchi rulings

Photodiodes

Laser scanners

Demodulation

Laser stabilization

RELATED CONTENT

Cross Talk Measurements On A Linear Array Of Deep U...
Proceedings of SPIE (August 11 1983)
An Apparatus For Wide Range Feedback Control Of ND YAG...
Proceedings of SPIE (January 01 1987)
Laser scatter in clinical applications
Proceedings of SPIE (February 22 2008)
Design And Application Of Laser Intensity Stabilizers At CRI
Proceedings of SPIE (January 30 1987)
Use of detectors with photoelastic modulators
Proceedings of SPIE (September 25 2002)

Back to Top