Paper
11 May 1987 Thermographic Observation Of Pyrotechnic Fuse Failure
Linda D. Abney, Jonathan H. Mohler
Author Affiliations +
Abstract
Certain metal combinations alloy, with release of large amounts of energy. Palladium/Aluminum is available commercially in the form of wire, braid and foil of various diameters and thicknesses. These products are useful as heat sources and as fuses to ignite other pyrotechnic compositions. We have found that when used in small devices, where the fuse wire may be required to go through narrow channels and sharp bends, the alloying reaction may not propagate reliably. We have used infrared thermography to monitor heat flow in the fuse wire and in materials surrounding it, to observe the thermal dynamics involved in fuse wire propagation. Fuse wire can be ignited by passing an electrical current through it from end to end or it can be lit from one end to carry ignition to other locations in a device or system. Two effects have been observed thermographically: Conductive cooling of the wire where effective thermal contact occurs and hot zone formation at stress points produced by sharp bends. Thermographic measurements have demonstrated that when electrical current is used to ignite palladium/aluminum wire or braid, reaction begins farthest from a heat sink region, or at a sharp bend.The problem with high thermal contact is easily understood since heat sinking can cool the fuse wire and retard reaction, even to the point of failure. Hot zone formation at high stress regions may, on the other hand, not appear detrimental. However, if one recognizes that these hot zones result from high electrical resistance, probably due to microscopic cracks formed in the palladium sheath of the fuse wire, it is easy to see that a corresponding thermal resistance will also be present. Such a high thermal resistance point, when coupled with adjacent conductive cooling paths can contribute to fuse failure.By using infrared scanning, one can not only observe the importance of such effects in fuse wire ignition and propagation but also see where they may be occurring in a particular configuration. Possible failure points can thus be avoided in device designs.
© (1987) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Linda D. Abney and Jonathan H. Mohler "Thermographic Observation Of Pyrotechnic Fuse Failure", Proc. SPIE 0780, Thermosense IX: Thermal Infrared Sensing for Diagnostics and Control, (11 May 1987); https://doi.org/10.1117/12.940513
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Resistance

Thermal effects

Thermography

Infrared radiation

Metals

Palladium

Electrical breakdown

RELATED CONTENT

The Plug Calibrator A Useful Analytical Device For...
Proceedings of SPIE (January 01 1988)
Meteorology And Infrared Measurements
Proceedings of SPIE (March 12 1982)
Weld electrode cooling study
Proceedings of SPIE (March 19 1999)
R-value estimation by local thermographic analysis
Proceedings of SPIE (May 03 2010)
Study of TCR of TiW alloy films deposited by magnetron...
Proceedings of SPIE (February 18 2011)

Back to Top