6 July 2018 Performance evaluation of a 3D structured phantom with simulated lesions on breast imaging systems
Author Affiliations +
Proceedings Volume 10718, 14th International Workshop on Breast Imaging (IWBI 2018); 107180Y (2018) https://doi.org/10.1117/12.2318472
Event: The Fourteenth International Workshop on Breast Imaging, 2018, Atlanta, Georgia, United States
Abstract
The purpose of this study is comparing the detection performance in 2D full field digital mammography (FFDM) and digital breast tomosynthesis (DBT) using a structured phantom with inserted target objects. The phantom consists of a semi-cylindrical PMMA container, filled with water and PMMA spheres of different diameters. Microcalcifications and 3D printed masses (spiculated and non-spiculated) were inserted. The phantom was imaged ten times in both modes of five systems, using automatic exposure control (AEC) and at half and double the AEC dose. Five readers evaluated target detectability in a four-alternative forced-choice study. The percentage of correct responses (PC) was assessed based on 10 trials of each reader for each object type, size, imaging modality and dose level. Additionally, detection threshold diameters at 62.5 PC were assessed via non-linear regression fitting of the psychometric curve. Evaluation of target detection in FFDM showed that spiculated masses were better detected compared to non-spiculated masses. In DBT, detection of both mass types increased significantly (p=0.0001) compared to FFDM. Microcalcification detection thresholds ranged between 110 and 118 μm and were similar for the five systems in FFDM while larger variations (106-158 μm) were found in DBT. Mass detection was independent of dose in FFDM while weak dependence was seen for DBT. Microcalcification detection increased with increasing dose for both modalities. The phantom was able to show detectability differences between FFDM and DBT mode for five commercial systems in line with the findings from clinical trials. We suggest to use the phantom for task-based assessment methods for acceptance and commissioning testing of DBT systems.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Liesbeth Vancoillie, Lesley Cockmartin, Kristina Tri Wigati, Dimitar Petrov, Guozhi Zhang, Nicholas Marshall, and Hilde Bosmans "Performance evaluation of a 3D structured phantom with simulated lesions on breast imaging systems", Proc. SPIE 10718, 14th International Workshop on Breast Imaging (IWBI 2018), 107180Y (6 July 2018); https://doi.org/10.1117/12.2318472
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Digital breast tomosynthesis

3D modeling

Target detection

3D image processing

Imaging systems

Polymethylmethacrylate

Breast

Back to Top