Abstract
The paper analyzes the image quality of video presented on the new AMLCD F/A-18 E/F multipurpose color display (MPCD) and compares it to the shadow-mask CRT based F/A-18 C/D MPCD. We focus on the contrast ratio advantages held by the AMLCD over the CRT and the resulting superior presentation of color map video and monochrome sensor video. We present modulation transfer functions (MTFs) for the E/F AMLCD and the C/D shadow-mask CRT, and combine these with the contrast threshold function (CTF) of the human visual system, to compute an objective image quality metric, the MTFA, that has been found to correlate well with performance in military detection and recognition tasks. The phase/space varying nature of the LCD requires the use of a multi-valued modulation transfer function (MMTF) in contrast to the single valued MTFs traditionally derived for phase/space invariant systems. The significant difference between the MTFAs for the E/F MPCD and the C/D MPCD highlight the superior image quality produced by the AMLCD. This superior image quality translates into better detection and recognition of target details from sensor video. Two additional metrics, the limiting resolution, and the SQRI, are also computed and used to confirm the overall conclusions.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
William P. Olson and Nikhil Balram "Video quality on AMLCD versus shadow-mask CRT", Proc. SPIE 2734, Cockpit Displays III, (30 May 1996); https://doi.org/10.1117/12.240998
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
LCDs

CRTs

Video

Modulation transfer functions

Modulation

Image quality

Sensors

RELATED CONTENT

Cross-display-technology video motion measurement tools
Proceedings of SPIE (February 23 2006)
Direct Measure Of Cathode-Ray Tube (CRT) Image Quality
Proceedings of SPIE (November 15 1979)
Application of AMLCDs to military aircraft displays
Proceedings of SPIE (September 14 1998)
Lower bound for LCD image quality
Proceedings of SPIE (March 11 1996)

Back to Top