27 February 1997 Neutron-induced photon response of an NE213 scintillation detector
T. Novotny, Sigmund Guldbakke, Horst Klein
Author Affiliations +
Proceedings Volume 2867, International Conference Neutrons in Research and Industry; (1997) https://doi.org/10.1117/12.267867
Event: Fifth International Conference on Applications of Nuclear Techniques: Neutrons in Research and Industry, 1996, Crete, Greece
Abstract
The response of an NE213 scintillator has been determined for photons induced in the detector assembly by neutrons with energies between 1 MeV and 16 MeV. Coupled MCNP4A/EGS4 Monte Carlo simulations were compared and adjusted to experimental data. The complete set of response matrices for neutrons, photons and neutron induced photons was then used to determined the spectral neutron and photon fluence of 239Pu/13C and 241Am/9Be sources.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
T. Novotny, Sigmund Guldbakke, and Horst Klein "Neutron-induced photon response of an NE213 scintillation detector", Proc. SPIE 2867, International Conference Neutrons in Research and Industry, (27 February 1997); https://doi.org/10.1117/12.267867