Paper
12 December 1997 Flash water-window x-ray generator with a ferrite capillary
Eiichi Sato, Michiaki Sagae, Toshio Ichimaru, Kazuyoshi Takayama, Kimio Sakamaki, Yoshiharu Tamakawa
Author Affiliations +
Abstract
The fundamental study on a flash water-window x-ray generator is described. This generator is composed of a high-voltage power supply, a polarity-inversion high-voltage pulser, a krytron pulser as a trigger device, an oil-diffusion pump, and a vacuum chamber with a capillary. A combined ceramic condenser of about 5 nF in the pulser is charged up to 70 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing a gap switch by the krytron pulser. In the present work, the chamber is evacuated by the pump with a pressure of about 1 by 10-3 Pa, and the titanium anode and cathode electrodes are employed to produce L-series characteristic x rays in the water-window range. The diameter and the length of the ferrite capillary are 2.0 and 30 mm, respectively. Both the cathode voltage and the discharge current displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were minus 24 kV and 2.8 kA, respectively. The pulse durations of the water-window x-rays were nearly equivalent to those of the damped oscillations of the voltage and current, and their values were less than 10 microseconds.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eiichi Sato, Michiaki Sagae, Toshio Ichimaru, Kazuyoshi Takayama, Kimio Sakamaki, and Yoshiharu Tamakawa "Flash water-window x-ray generator with a ferrite capillary", Proc. SPIE 3173, Ultrahigh- and High-Speed Photography and Image-based Motion Measurement, (12 December 1997); https://doi.org/10.1117/12.294501
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Capillaries

X-rays

Power supplies

Ceramics

Electrodes

Protactinium

Switches

RELATED CONTENT

Observation of soft x ray amplification in Ne like Ar...
Proceedings of SPIE (December 21 2005)
Flash water-window x-ray generator WFX-98
Proceedings of SPIE (June 22 1999)
Dual-energy flash x-ray generator
Proceedings of SPIE (May 30 1995)
Water window flash x ray production from linear plasma x...
Proceedings of SPIE (December 18 2000)

Back to Top