10 November 1998 Calibration and preliminary results on the performance of the XMM EPIC PN flight camera: imaging modes
Ulrich G. Briel, Heinrich W. Braeuninger, Konrad Dennerl, C. Greiveldinger, Frank Haberl, Gisela D. Hartner, Norbert Meidinger, Norbert Krause, Martin Popp, Elmar Pfeffermann, Claus Reppin, Th. Stadelbauer, Lothar Strueder, Joachim E. Truemper, Edgar Bihler, Willy Grubmiller, Eckhard Kendziorra, Marcus Kirsch, Markus Kuster, Bernhard Pflueger, Peter Holl, Josef Kemmer, Heike Soltau, Christoph von Zanthier
Author Affiliations +
Abstract
The x-ray multi mirror (XMM) mission, the second cornerstone of the European Space Agency's Horizon 2000 program, will be launched in August 1999 and will perform high throughput imaging and spectroscopy in the energy range form 0.1 to 15 keV. One of the focal plane instruments is the EPIC pn CCD camera with a sensitive area of 60 mm by 60 mm, integrated on a single silicon wafer. The camera is divided into 4 redundant quadrants of three 10 mm by 30 mm CCDs with 64 by 200 pixels each. The thin entrance window in combination with a depletion depth out modes give the flexibility to observe targets of different source strength up to several Grab with some reduction in spectral and spatial performance. We will report on the calibration of the flight unit of the EPIC pm camera, performed at the long beam test facility Panter in Muenchen and at the Synchrotron Radiation Facility beam lines at the Istitute d'Astrophysique Spatiale in Orsay. In this paper we describe the preliminary results of the calibration of the imaging modes.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ulrich G. Briel, Heinrich W. Braeuninger, Konrad Dennerl, C. Greiveldinger, Frank Haberl, Gisela D. Hartner, Norbert Meidinger, Norbert Krause, Martin Popp, Elmar Pfeffermann, Claus Reppin, Th. Stadelbauer, Lothar Strueder, Joachim E. Truemper, Edgar Bihler, Willy Grubmiller, Eckhard Kendziorra, Marcus Kirsch, Markus Kuster, Bernhard Pflueger, Peter Holl, Josef Kemmer, Heike Soltau, and Christoph von Zanthier "Calibration and preliminary results on the performance of the XMM EPIC PN flight camera: imaging modes", Proc. SPIE 3445, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy IX, (10 November 1998); https://doi.org/10.1117/12.330294
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Charge-coupled devices

Cameras

X-rays

Quantum efficiency

Sensors

Point spread functions

RELATED CONTENT

Testing fully depleted CCD
Proceedings of SPIE (July 28 2014)
Development of CCD cameras for soft x ray imaging at...
Proceedings of SPIE (September 26 2013)
Status of the calibration of the EPIC pn camera onboard...
Proceedings of SPIE (February 03 2004)
Status of the EPIC/MOS calibration onboard XMM-Newton
Proceedings of SPIE (March 11 2003)
Ground calibration of the XMM EPIC MOS cameras at the...
Proceedings of SPIE (October 22 1999)
PN CCD camera for XMM performance of high time...
Proceedings of SPIE (October 15 1997)

Back to Top