Paper
10 November 1998 Ground-calibration GSE for the XMM-EPIC instrument at the Orsay Synchrotron facility
Massimo Trifoglio, Fulvio Gianotti, John Buchan Stephen, M. Balasini, Jean-Francois E. Hochedez, Lucio Chiappetti, R. A. Glukhov, Olivier Hainaut, Erick Jourdain, Nicola La Palombara, Philippe B. Marty, T. Moreno, C. Musso
Author Affiliations +
Abstract
The European Photon Imaging Camera (EPIC) is one of the major instruments on board the European Space Agency's X-ray Multi-Mirror cornerstone mission planned for launch at the end of the century. Ground calibrations have been performed in 1997 and 1998 on the electrical and flight models of the MOS-CCD and on the flight model of the p-n-CCD focal plane cameras at he Synchrotron facility at IAS Orsay in France. The complexity of the imaging systems required a correspondingly sophisticated calibration equipment, capable of automatically setting and calibrating the synchrotron beam at a particular energy, controlling the camera head movement in synchronism with the CCD frame readout, initializing the instrument and acquiring both the instrument data and the facility monitor data in realtime. Furthermore, always in real-time, the data stream was unpacked and stored as photon lists in FITS format and made available via NFS to the off-line analysis software. Contemporaneously, a quick look program allowed the operator to continuously monitor the calibration procedure from a scientific point of view, ensuring the correct operation of the system. The calibration system from the point of view of the instrument and the current status of the project is described.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Massimo Trifoglio, Fulvio Gianotti, John Buchan Stephen, M. Balasini, Jean-Francois E. Hochedez, Lucio Chiappetti, R. A. Glukhov, Olivier Hainaut, Erick Jourdain, Nicola La Palombara, Philippe B. Marty, T. Moreno, and C. Musso "Ground-calibration GSE for the XMM-EPIC instrument at the Orsay Synchrotron facility", Proc. SPIE 3445, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy IX, (10 November 1998); https://doi.org/10.1117/12.330287
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Cameras

Data archive systems

Synchrotrons

X-rays

Data acquisition

CCD cameras

RELATED CONTENT

Design and testing of a low cost x ray CCD...
Proceedings of SPIE (October 22 1999)
XMM-Newton satellite MOS CCD detectors calibration results
Proceedings of SPIE (November 28 2000)
Status of the EPIC/MOS calibration onboard XMM-Newton
Proceedings of SPIE (March 11 2003)
Ground calibration of the XMM EPIC MOS cameras at the...
Proceedings of SPIE (October 22 1999)
EPIC system onboard the ESA XMM
Proceedings of SPIE (October 31 1996)

Back to Top