Paper
18 June 1999 Noncontact measurement of intraocular pressure using a modified Michelson interferometer
Joerg Drescher, Wilhelm Stork, Stefan Hey, Arnd Gundlach, Klaus-Dieter Mueller-Glaser, Christine F. Kreiner
Author Affiliations +
Proceedings Volume 3591, Ophthalmic Technologies IX; (1999) https://doi.org/10.1117/12.350571
Event: BiOS '99 International Biomedical Optics Symposium, 1999, San Jose, CA, United States
Abstract
This paper describes a new method to examine the intraocular pressure (IOP) without any contact with the eye. In our new approach the IOP is determined indirectly from the acoustic properties of the eye, as the resonance frequencies of the bulbus are shifting with increasing IOP. In a first step simulations were made with the Finite Element Method to explore the correlation between the IOP and the acoustic properties of the bulbus. The results showed a significant rise of the resonance-frequencies with increasing IOP. Simultaneously a in-vitro measurement system was built comprising a modified michelson interferometer to measure the vibrations, a transducer to stimulate the eye and a controlling PC. With this system measurements were made with artificial eyes and enucleated pig eyes to prove the correlation experimentally. The eyes were stimulated both contacting the eye with a transducer by a stick and contactless with sonic waves. Several series of measurements showed a proportional constant of 1,25 Hz/mmHg in average, which can be detected easily. The standard deviation measuring different pig eyes was 4,5 mmHg. Next a in-vivo system was developed to study the acoustic behavior of the human eye in the real environment. The in-vivo system consists of a miniaturized semiconductor-laser interferometer complying laser safety requirements, an automatic positioning unit and an excitation unit to stimulate vibrations of the eye. Sub-micrometer vibrations of the eye can be measured in-vivo with this system.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Joerg Drescher, Wilhelm Stork, Stefan Hey, Arnd Gundlach, Klaus-Dieter Mueller-Glaser, and Christine F. Kreiner "Noncontact measurement of intraocular pressure using a modified Michelson interferometer", Proc. SPIE 3591, Ophthalmic Technologies IX, (18 June 1999); https://doi.org/10.1117/12.350571
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Eye

Cornea

In vivo imaging

Interferometers

Acoustics

Eye models

In vitro testing

Back to Top