Paper
22 September 2003 Model tests of dynamic parameters of double hot-wire anemometer method
Pawel Ligeza
Author Affiliations +
Proceedings Volume 5124, Optoelectronic and Electronic Sensors V; (2003) https://doi.org/10.1117/12.517136
Event: Optoelectronic and Electronic Sensors V, 2002, Rzeszow, Poland
Abstract
Hot-wire measurements in non-isothermal flows require temperature compensation or correction. One of the solutions is the system of two hot-wire anemometers which enable to measure velocity and temperature in non-isothermal gas flows. The output signals come from two hot-wire anemometers operating at different overheat ratio. As the two sensors operate in a CTA mode, we get a wide range of frequency bandwidth for velocity and temperature measurements. This paper presents the results of modeling and optimization of a double hot-wire anemometer system providing temperature correction of anemometric signal.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Pawel Ligeza "Model tests of dynamic parameters of double hot-wire anemometer method", Proc. SPIE 5124, Optoelectronic and Electronic Sensors V, (22 September 2003); https://doi.org/10.1117/12.517136