Abstract
Stereoscopic video teaching can facilitate understanding for current minimally-invasive operative techniques. This project was created to set up a digital stereoscopic teaching environment for training of ENT residents and medical students. We recorded three ENT operative procedures (tympanoplasty, paranasal sinus operation and laser chordectomy) at the University Hospital Aachen. The material was edited stereoscopically at the Waseda University and converted into a streaming 3-D video format, which does not depend on PAL or NTSC signal standards. Video clips were evaluated by 5 ENT specialists and 11 residents in single sessions on an LCD monitor (8) and a CRT monitor (8). Emphasis was laid on depth perception, visual fatigue and time to achieve stereoscopic impression. Qualitative results were recorded on a visual analogue scale, ranging from 1 (excellent) to 5 (bad). The overall impression was rated 2,06 to 3,13 in the LCD group and 2,0 to 2,62 in the CRT group. The depth impression was rated 1,63 to 2,88 (LCD) and 1,63 to 2,25 (CRT). Stereoscopic video teaching was regarded as useful in ENT training by all participants. Further points for evaluation will be the quantification of depth information as well as the information gain in teaching junior colleagues.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Justus Ilgner M.D., Takashi Kawai, Martin Westhofen M.D., and Takashi Shibata "Production and evaluation of stereoscopic video presentation in surgical training", Proc. SPIE 5291, Stereoscopic Displays and Virtual Reality Systems XI, (21 May 2004); https://doi.org/10.1117/12.524274
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Video

LCDs

CRTs

Surgery

Visualization

Video processing

Glasses

RELATED CONTENT

Solving bezel reliability and CRT obsolescence
Proceedings of SPIE (September 10 2003)
What every surgeon wants practical aspects on the use...
Proceedings of SPIE (February 18 2010)
Telepresence microsurgery system
Proceedings of SPIE (June 05 1998)
AMLCD head-down displays for avionic applications
Proceedings of SPIE (February 07 1997)

Back to Top