Paper
12 January 2009 Inductosyn angle measuring system error based on AD2S80 resolver-to-digital converter
Zhenhuan Wang, Xijun Chen, Ren Li
Author Affiliations +
Proceedings Volume 7133, Fifth International Symposium on Instrumentation Science and Technology; 71331B (2009) https://doi.org/10.1117/12.810456
Event: International Symposium on Instrumentation Science and Technology, 2008, Shenyang, China
Abstract
This paper presents an inductosyn angle measurement system based on AD2S80 resolver-to-digital converter. The reason why the reference signal is not orthogonal with the excitation signal is analyzed, and a mathematical model is established for the error. The correctness of the error model is proved by measuring data. The error that the reference signal not be orthogonal with the stimulating magnetism signal causes the quadratic sine harmonic error which has a significant effect on the precision of the angle measurement system.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhenhuan Wang, Xijun Chen, and Ren Li "Inductosyn angle measuring system error based on AD2S80 resolver-to-digital converter", Proc. SPIE 7133, Fifth International Symposium on Instrumentation Science and Technology, 71331B (12 January 2009); https://doi.org/10.1117/12.810456
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
Back to Top