10 March 2009 High temporal resolution cardiac cone-beam CT using a slowly rotating C-arm gantry
Guang-Hong Chen, Jie Tang, Brian Nett, Shuai Leng, Joseph Zambelli, Zhihua Qi, Nick Bevins, Scott Reeder, Howard Rowley
Author Affiliations +
Proceedings Volume 7258, Medical Imaging 2009: Physics of Medical Imaging; 72580C (2009) https://doi.org/10.1117/12.813810
Event: SPIE Medical Imaging, 2009, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
Purpose: To achieve three dimensional isotropic dynamic cardiac CT imaging with high temporal resolution for evaluation of cardiac function with a slowly rotating C-arm system. Method and Materials: A recently introduced extension to compressed sensing, viz. Prior Image Constrained Compressed Sensing (PICCS), in which a prior image is used as a constraint in the reconstruction has enabled this application. An in-vivo animal experiment (e.g. a beagle model) was conducted using an interventional C-arm system. The imaging protocol was as follows: contrast was injected, the contrast equilibrated, breathing was suspended for ~14 seconds during which time 420 equally spaced projections were acquired. This data set was used to reconstruct a fully sampled blurred image volume using the conventional FDK algorithm (e.g. the prior image). Then the data set was retrospectively gated into 19 phases according to the recorded ECG signal (heart rate ~ 95bpm) and images were reconstructed with the PICCS algorithm. Results: Cardiac MR was used as the gold standard due to its high temporal resolution. The same short-axis slice was selected from the PICCS-CT data set and the MR data set. Manual contouring on the peak systolic and peak diastolic frames was performed to assess the ejection fraction contribution from this single plane. The calculated ejection fractions with PICCS-CT agreed well with the MR results. Conclusion: We have demonstrated the ability to use a slowly rotating interventional C-arm system in order to make measurements of cardiac function. The new technique provides high isotropic spatial resolution (~0.5 mm) along with high temporal resolution (~ 33 ms). The evaluation of cardiac function demonstrated a great agreement with single slice cardiac MR.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Guang-Hong Chen, Jie Tang, Brian Nett, Shuai Leng, Joseph Zambelli, Zhihua Qi, Nick Bevins, Scott Reeder, and Howard Rowley "High temporal resolution cardiac cone-beam CT using a slowly rotating C-arm gantry", Proc. SPIE 7258, Medical Imaging 2009: Physics of Medical Imaging, 72580C (10 March 2009); https://doi.org/10.1117/12.813810
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Reconstruction algorithms

Data acquisition

Heart

Temporal resolution

Computed tomography

Compressed sensing

Image restoration

Back to Top