Paper
22 February 2012 Reproducibility of crosstalk measurements on active glasses 3D LCD displays based on temporal characterization
Sylvain Tourancheau, Kun Wang, Jarosław Bułat, Romain Cousseau, Lucjan Janowski, Kjell Brunnström, Marcus Barkowsky
Author Affiliations +
Proceedings Volume 8288, Stereoscopic Displays and Applications XXIII; 82880Y (2012) https://doi.org/10.1117/12.908082
Event: IS&T/SPIE Electronic Imaging, 2012, Burlingame, California, United States
Abstract
Crosstalk is one of the main display-related perceptual factors degrading image quality and causing visual discomfort on 3D-displays. It causes visual artifacts such as ghosting effects, blurring, and lack of color fidelity which are considerably annoying and can lead to difficulties to fuse stereoscopic images. On stereoscopic LCD with shutter-glasses, crosstalk is mainly due to dynamic temporal aspects: imprecise target luminance (highly dependent on the combination of left-view and right-view pixel color values in disparity regions) and synchronization issues between shutter-glasses and LCD. These different factors influence largely the reproducibility of crosstalk measurements across laboratories and need to be evaluated in several different locations involving similar and differing conditions. In this paper we propose a fast and reproducible measurement procedure for crosstalk based on high-frequency temporal measurements of both display and shutter responses. It permits to fully characterize crosstalk for any right/left color combination and at any spatial position on the screen. Such a reliable objective crosstalk measurement method at several spatial positions is considered a mandatory prerequisite for evaluating the perceptual influence of crosstalk in further subjective studies.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Sylvain Tourancheau, Kun Wang, Jarosław Bułat, Romain Cousseau, Lucjan Janowski, Kjell Brunnström, and Marcus Barkowsky "Reproducibility of crosstalk measurements on active glasses 3D LCD displays based on temporal characterization", Proc. SPIE 8288, Stereoscopic Displays and Applications XXIII, 82880Y (22 February 2012); https://doi.org/10.1117/12.908082
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image transmission

Glasses

LCDs

3D displays

3D metrology

Chromium

Transmittance

Back to Top