8 May 2012 The refractive index measurement technique based on the defocus correction method in full-field optical coherence tomography
Author Affiliations +
Abstract
We propose and demonstrate a novel refractive index (RI) measurement by using the numerical-sample-motion based the defocus correction method in full field optical coherence tomography (FF-OCT). Overcoming the general problem in FFOCT that is the position of the focal plane is separated from the position of the image plane when imaging a deep region inside a sample, we measure the separation distance from the position of the focal plane to the position of the image plane. The RI is determined from the separation distance that is obtained by the numerically adjusted distance of a sample position. With the proposed method, the depth resolved RIs of double layer materials are determined.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Gihyeon Min, Ju Wan Kim, and Byeong-Ha Lee "The refractive index measurement technique based on the defocus correction method in full-field optical coherence tomography", Proc. SPIE 8428, Micro-Optics 2012, 84281M (8 May 2012); https://doi.org/10.1117/12.922398
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image resolution

Optical coherence tomography

Refractive index

Distance measurement

Charge-coupled devices

Target acquisition

Beam splitters