|
1.IntroductionFunctional near-infrared spectroscopy (fNIRS)1 has been used for observing brain activity in the fields that require everyday measurements because the equipment is smaller, more inexpensive, and requires less restriction of subjects than other neuro-imaging modalities such as functional MRI and PET. Since the light is irradiated and detected from the brain through the scalp, the effects of hemodynamic changes in the scalp on the fNIRS signals have been reported.2,3 Therefore, an experimental design that compensates these effects using adequate control conditions is required. To lift or relax this limitation, several engineering techniques have been developed.4–6 The multidistance independent analysis (MD-ICA) method using multidistance optodes7 has an advantage in that scalp signals can be quantitatively separated from the obtained signals. However, the real-time process of MD-ICA has not been achieved due to ICA, which requires time series data, although some other techniques are applicable for real-time processing. Because the scalp-signal effect potentially changes during experiments due to changes in emotion, the real-time separation is helpful to determine whether to stop or redo the experiment to increase measurement throughput. The real-time separation is also required for the brain-computer interface and neuro-feedback systems that have been applied in rehabilitation. We modified the algorithm of MD-ICA for real-time processing and validated the algorithm through an experiment using a dynamic phantom. 2.MethodThe absorbance change is proportional to the sum of the product of change in hemoglobin concentration and partial path length in region according to the modified Beer–Lambert equation in the case where the changes in partial path lengths are negligible where is the molecular extinction coefficient for hemoglobin. Since the continuous-wave fNIRS (cw-fNIRS) cannot separately measure and , the effective values of and are defined when the hemoglobin concentration changes in the scalp and the deep tissueThe dependency of the partial path length on the source-detector (SD) distance has been calculated using a slab model7 and the real-head anatomical model obtained through MRI.8 The partial path length in scalp is approximately constant when is larger than about 10 mm. The partial path length in the deep tissue linearly increases when is larger than . Here, and are the -intercept and the minus value of -intercept, respectively, when the partial path length in the deep tissue is plotted to .In MD-ICA, independent components were calculated by time-delayed decorrelation ICA (TDD-ICA) using absorbance changes observed with multiple values of , then each weight factor for each independent component was divided into a deep subcomponent and a scalp subcomponent according to the ratio of the partial path length for deep tissue and scalp calculated using the dependency of signal intensity. The deep and scalp components were reconstructed using all deep subcomponents and scalp subcomponents, respectively. The TDD algorithm requires a certain time period of measured absorbance changes, usually the period of a measurement cycle. Therefore, MD-ICA was used in the postprocess. The MD-ICA algorithm can be easily modified for real-time processing by removing the ICA process. We call the new algorithm the real-time scalp signal separating (RT-SSS) algorithm. In MD-ICA, the separation process was applied to each independent component obtained by ICA. In RT-SSS, the separation process was applied not to the independent component, but directly to the absorbance change. The absorbance change observed with SD distance , can be separated into those for the deep and scalp layers, and using Eqs. (2) and (3). The and can be calculated for each time from and observed with different two values of , and , when is given as well as MD-ICA. The parameters and are effective ones for the two homogeneous layer models. The deviation of caused by the inhomogeneity in the depth direction leads to the cross talk between the separated signals of scalp and deep regions. The errors of separation were investigated in the previous paper for MD-ICA.7 Although two values of are required for solving equations, using more than three values of potentially reduces the error of separation due to the lateral inhomogeneity of absorbance in the scalp caused by the inhomogeneous distribution of scalp veins. In RT-SSS, the noise is artificially divided into scalp and deep components depending on its SD-distance dependency. Each noise included in scalp or deep signals can be reduced by the usual algorithms of noise reduction in the postprocess. 3.Experimental Validation Using a Dynamic PhantomThe RT-SSS algorithm was validated using a dynamic phantom.9 The dynamic phantom had two (upper and lower) scattering and absorbing layers, and the absorption changes in the two layers were independently created by their motions driven by two moving stages. We measured the absorbance changes by using the phantom irradiated by a diode-laser light with a wavelength of 695 nm at and 30 mm under three conditions: (1) only the absorption of the lower layer was changed with a specified activation pattern, (2) only the absorption of the upper layer was changed with another activation pattern, and (3) the absorptions of both the lower and upper layers were changed with the activation patterns used for the conditions 1 and 2, respectively. When considering that is commonly employed in fNIRS, the absorbance change measured at under condition 1 was the pure signal originating from the deep (lower) layer. The absorbance change measured at under condition 2 was the pure signal originating from the scalp (upper) layer. The absorbance change measured at under condition 3 was the mixed signal originating from both the deep and scalp layers. These three absorbance changes are expressed as , , and , respectively. The absorbance changes in the deep and scalp layers obtained using the RT-SSS algorithm with and are also expressed as and , respectively. The value of for the phantom required the use of Eq. (5). It was experimentally measured as follows. Under condition 1, of Eq. (5) can be replaced by . Then, we can write the following equation: By the least square fitting with Eq. (7), was obtained as 9.92 mm. Note that these values change depending on the characteristics of the phantom, i.e., materials, structure, and so on.The mixed absorbance change measured with , and the separated deep and scalp absorbance changes using the RT-SSS algorithm, and are compared with the pure absorbance changes and in Fig. 1. Each absorbance change separated using the RT-SSS algorithm agreed with each pure absorbance change for both deep and scalp tissues. Figure 2 shows the correlation between (a) the deep absorbance change, (b) scalp absorbance change and each corresponding pure absorbance change, and (c) the mixed absorbance change and pure deep absorbance change. The fitting coefficients, slope and -intercept , are shown in Fig. 2. The correlation coefficients between the RT-SSS absorbance change and pure absorbance change for deep tissue and scalp were 0.997 and 0.991, respectively. The chi-squares were small enough and the residual waveform was flat. For the mixed absorbance change, however, the correlation coefficient was smaller, the chi-square was larger, and the residual waveform was more distorted than those for RT-SSS absorbance change because the mixed absorbance change includes both deep and scalp ones. Therefore, we can conclude that the RT-SSS algorithm successfully separated the mixed absorbance change into deep and scalp absorbance changes. 4.Discussions and ConclusionsThe RT-SSS algorithm was explicitly applied to oxygenated and deoxygenated hemoglobin measurements using two wavelengths. From Eqs. (4) to (6), each absorbance change at wavelengths and measured with and was written as with where and represent the molecular extinction coefficient at wavelength for oxygenated and deoxygenated hemoglobins, respectively. Also and are the change in concentration of oxygenated and deoxygenated hemoglobins, respectively. Here, was assumed to be independent of the wavelength in the case of human measurement. When and are given, the deep and scalp hemoglobin signals are separated by solving Eq. (8) for four unknowns of , , and since the elements of the matrix on the left-hand side of Eq. (8) are directly measurable at each time, . The literature values of for hemoglobin can be used. The value of for the human forehead was estimated to be by stanching the scalp blood flow, and the errors in the calculated hemoglobin caused by the variation in the value of were also estimated in the previous paper on MD-ICA.7 Because the concept of RT-SSS is almost the same as that of MD-ICA, the effect of the variation of must also be almost the same.In conclusion, we proposed the RT-SSS algorithm using two measurements and validated it through phantom experiments. This algorithm will be applied to human experiments to verify its effectiveness. ReferencesF. Scholkmannet al.,
“A review on continuous wave functional near-infrared spectroscopy and imaging instrumentation and methodology,”
Neuroimage, 85 6
–27
(2014). http://dx.doi.org/10.1016/j.neuroimage.2013.05.004 NEIMEF 1053-8119 Google Scholar
P. Smielewskiet al.,
“Clinical evaluation of near-infrared spectroscopy for testing cerebrovascular reactivity in patients with carotid artery disease,”
Stroke, 28 331
–338
(1997). http://dx.doi.org/10.1161/01.STR.28.2.331 SJCCA7 0039-2499 Google Scholar
L. Minatiet al.,
“Intra- and extra-cranial effects of transient blood pressure changes on brain near-infrared spectroscopy (NIRS) measurements,”
J. Neurosci. Methods, 197 283
–288
(2011). http://dx.doi.org/10.1016/j.jneumeth.2011.02.029 JNMEDT 0165-0270 Google Scholar
D. A. BoasA. M. DaleM. A. Franceschini,
“Diffuse optical imaging of brain activation: approaches to optimizing image sensitivity, resolution, and accuracy,”
Neuroimage, 23
(Suppl 1), S275
–S288
(2004). http://dx.doi.org/10.1016/j.neuroimage.2004.07.011 NEIMEF 1053-8119 Google Scholar
R. B. SaagerN. L. TelleriA. J. Berger,
“Two-detector corrected near infrared spectroscopy (C-NIRS) detects hemodynamic activation responses more robustly than single-detector NIRS,”
Neuroimage, 55 1679
–1685
(2011). http://dx.doi.org/10.1016/j.neuroimage.2011.01.043 NEIMEF 1053-8119 Google Scholar
T. YamadaS. UmeyamaK. Matsuda,
“Multidistance probe arrangement to eliminate artifacts in functional near-infrared spectroscopy,”
J. Biomed. Opt., 14 064034
(2009). http://dx.doi.org/10.1117/1.3275469 JBOPFO 1083-3668 Google Scholar
T. Funaneet al.,
“Quantitative evaluation of deep and shallow tissue layers’ contribution to fNIRS signal using multi-distance optodes and independent component analysis,”
Neuroimage, 85 150
–165
(2014). http://dx.doi.org/10.1016/j.neuroimage.2013.02.026 NEIMEF 1053-8119 Google Scholar
G. E. StrangmanQ. ZhangZ. Li,
“Scalp and skull influence on near infrared photon propagation in the Colin27 brain template,”
Neuroimage, 85 136
–149
(2014). http://dx.doi.org/10.1016/j.neuroimage.2013.04.090 NEIMEF 1053-8119 Google Scholar
T. Funaneet al.,
“Dynamic phantom with two stage-driven absorbers for mimicking hemoglobin changes in superficial and deep tissues,”
J. Biomed. Opt., 17 047001
(2012). http://dx.doi.org/10.1117/1.JBO.17.4.047001 JBOPFO 1083-3668 Google Scholar
|