Femtosecond MeV electron beam generated by laser-plasma accelerators (LPA) is a promising source for ultrafast electron diffraction (UED) application. Compared to conventional UED instruments which limit temporal resolution to a few tens of fs, plasma electron accelerator-based UED is possible to make sub-10 fs temporal resolution because of no intrinsic time jitter between pump-probe pulses and ultrashort electron bunch length. Some groups have shown that a few MeV electron beam can be produced by using a few mJ laser pulse as it has shorter pulse duration (single- or few-cycle). In this regime, the laser pulse is tightly focused onto gas target, and thus electrons in relatively high density plasma (1020 cm-3) are self-injected and accelerated. However, the electron beam quality like energy spread and emittance should be still improved for applications. Here, we introduce plan of two laser pulses-based plasma electron acceleration research for UED application at Pohang Accelerator Laboratory (PAL). A laser pulse is separated to two pulses that one is used to drive plasma wakefield and the other one is delivered to induce electron injection in a plasma bubble. Since the driving pulse intensity is retained under threshold of self-injection to suppress electron injection, the electron injection occurs in a localized region the injection pulse is focused, resulting in the high quality electron generation. In addition, researches conducting for better electron beam quality are presented in this presentation.
PAL-XFEL has operated general user program successfully from 2017 in both hard (2.5 – 14 keV) and soft (250 – 1300 eV) X-ray beamlines. Particularly in Soft X-ray Scattering and Spectroscopy (SSS) beamline, X-ray absorption and emission spectroscopy (XAS / XES) endstation has conducted general user programs.
In SSS beamline, second experimental instrument, Resonant Soft X-ray Scattering (RSXS) endstation, was built and open from 2020. This endstation mainly supports optical laser pump (800-nm-wavelength and harmonics) soft X-ray probe (400-1300 eV, covers 3d transition metal L2,3-edge, O K-edge, and part of 5f rare-earth element M4,5-edge) time-resolved RSXS experiments, with a time resolution better than 100 fs. Within less than a year, there have been several successful experiments, mainly in 3d transition metal compounds which are important magnetic and strongly correlated materials. The details of the endstation and selected experimental results will be introduced in the presentation.
Comparing a conventional undulator, the concept of plasma undulator is hard to realize because of a small-scaled cavity structure and a longitudinal acceleration field in the plasma cavity. So, the electron beam with betatron motion should stay in the longitudinal center of the plasma cavity. An other issue is the plasma cavity should propagate keeping a stable cavity formation and speed for entire plasma target. Moreover, high photon energy like UV and soft x-ray is much challenge since it requires longer plasma length and higher speed plasma cavity. To satisfy such conditions we investigate the electron beam-driven plasma cavity using PIC simulations. The life-time of the plasma cavity depends on how long the driving electron beam survives. We test several plasma profile, electron beam, and plasma lens parameters by testing matching conditions of the electron beam. In the presentation we also introduce new numerical technique in PIC to eliminate the numerical Cherenkov radiation causing unwanted increases of emittance. Finally we discuss a possibility of FEL from electron’s betraon motions.
Laser plasma wakefield accelerations (LWFA) are the most promising candidates for future compact accelerators and also can be used for next-generation free-electron lasers (FELs). However, due to the insufficient electron beam quality, such as a few percent of energy spread, stability, and reproducibility, the electron beam from the LWFA has difficulty to be directly used for FELs with a range from soft X-ray to hard X-ray. To overcome this limitation of the beam quality from the laser wakefield acceleration using various injection techniques, one of the most reliable way is to use the electron beam with short duration, lower energy spread, and emittance from the RF photocathode.
This external injection technique is planning with conventional S-band RF photocathode gun and final energy of 70 MeV, few tens fs duration, and lower emittance at Pohang Accelerator Laboratory Injector Test Facility (PAL-ITF). In this presentation, we show a simulation result on the characterization of the electron beam from LWFA using external injection for soft X-ray free-electron lasers.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.