16 March 2006 Investigation of foreign objects in soft-tissue using a PE-CMOS ultrasound system: a preliminary comparative study
Chu-Chuan Liu, Shih-Chung Ben Lo, Matthew T. Freedman, Marvin E. Lasser, Bob Lasser, John Kula, Yue Joseph Wang, Tsung-I Hsieh, Anita Sarcone
Author Affiliations +
Abstract
In this study, we have tested the ability of four imaging modalities to investigate foreign objects in soft tissue. We inserted wood, plastic, glass, and aluminum objects into a pork sample to simulate traumatized soft tissue. Each object was inserted into the skin, then passed through the fat tissue layer and penetrated into the muscle layer. We then took images of the pork sample using four different modalities: (1) a C-Scan imaging prototype which consists of an unfocused transducer, a compound acoustic lens, and a 2D ultrasound sensor array based on the piezoelectric sensing complementary metal-oxide semiconductor (PE-CMOS) technology; (2) a portable B-Scan ultrasound system; (3) a conventional X-ray system; (4) and a computed radiography (CR) X-ray system. We found that the aluminum and glass objects were clearly visible in both conventional X-ray and CR X-ray images with good contrast-to-noise ratio (CNR); however, the wood and plastic objects could not be clearly seen using these modalities. However, we found that the wood, plastic, and glass objects, as well as the thicker aluminum object, were clearly visible in the C-Scan ultrasound images. Furthermore, the fold fibro structures of the fat and muscle tissues in the pork were observable using this modality. The C-Scan prototype images produce neither speckle nor geometry distortion. Both of these issues are commonly seen in B-Scan ultrasound. The results of this study also indicate that the C-Scan images have better CNRs for most foreign objects when compared to other imaging modalities.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Chu-Chuan Liu, Shih-Chung Ben Lo, Matthew T. Freedman, Marvin E. Lasser, Bob Lasser, John Kula, Yue Joseph Wang, Tsung-I Hsieh, and Anita Sarcone "Investigation of foreign objects in soft-tissue using a PE-CMOS ultrasound system: a preliminary comparative study", Proc. SPIE 6147, Medical Imaging 2006: Ultrasonic Imaging and Signal Processing, 61470K (16 March 2006); https://doi.org/10.1117/12.654105
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Ultrasonography

X-ray imaging

X-rays

Imaging systems

Aluminum

Tissues

Chromium

Back to Top