Paper
1 April 2011 Geometrically induced dose correction: method and performance results
Author Affiliations +
Proceedings Volume 7985, 27th European Mask and Lithography Conference; 79850S (2011) https://doi.org/10.1117/12.895205
Event: 27th European Mask and Lithography Conference, 2011, Dresden, Germany
Abstract
For current and future semiconductor technology nodes with critical dimensions of 32 nm or below, the e-beam lithography is faced with increasing challenges to achieve a reasonable patterning of structures, especially if a process with a chemically amplified resist is used. The reasons for these limitations are the physical properties of the transfer process used to print a structure onto the resist-coated substrate, which inherently contains an unavoidable blurring of the deposited e-beam energy around the desired shape. This blurring is usually described by a so called process proximity function (PPF) and mostly approximated by a superposition of two or more Gaussian functions. The PPF includes the e-beam blur, electron forward scattering and resist effects (often described altogether by the so called alpha parameter of the PPF [K. Keil et al, "Resolution and total blur: Correlation and focus-dependencies in e-beam lithography," J. Vac. Sci. Technol. B 27, 2722 (2009)]) as well as the backscattering effect (often described by the so called beta parameter of the PPF). When the desired critical dimensions of structures are near or below the alpha parameter of the PPF, depending on their environment it may be just impossible to print the structures because of the vanishing image contrast. The PPF model confirms this well-known behavior but also shows ways and limits for improvements. This paper provides real pattern lithography results - comparing classical and GIDC correction - for exposures done on a Vistec SB3050DW shaped e-beam writer. A performance comparison of the GIDC method and the classical dose correction in terms of data preparation and writing time is presented.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
R. Galler, K.-H. Choi, M. Gutsch, C. Hohle, M. Krueger, L. E. Ramos, M. Suelzle, and U. Weidenmueller "Geometrically induced dose correction: method and performance results", Proc. SPIE 7985, 27th European Mask and Lithography Conference, 79850S (1 April 2011); https://doi.org/10.1117/12.895205
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Electron beam lithography

Line edge roughness

Cadmium sulfide

Cadmium

Chemically amplified resists

Photoresist processing

Backscatter

Back to Top