In high power regimes, broad area semiconductor lasers usually suffer from poor beam quality due to their asymmetric beam divergence, large beam quality factor (M2) and from the absence of any intrinsic filtering mechanism that can be integrated inside the cavity. In this work, we present a compact photonic crystal spatial filter, fabricated by periodically modulating refractive index media on a glass substrate using tightly focused femtoseconds laser. This filter work by deflecting the higher angular field components in a given frequency range. We demonstrate the spatial filtering effect when placed in an extended cavity configuration for a single BAS emitter, with transverse width of 400-μm and cavity length 1500-μm. We report a decrease of the laser M2 value along the slow axis with the introduction of the photonic crystal inside the cavity, together with a brightness enhancement by a factor of 1.5 compared to that of an unfiltered case. These results were compared with those obtained in the far-field domain, with a conventional spatial filter consisting of an intra-cavity slit.
Multi-wavelength laser sources are necessary for a functional photoacoustic (PA) spectroscopy. The use of high-power diode lasers (HPDLs) has aroused great interest for their relatively low costs and small sizes if compared to solid state lasers. However, HPDLs are only available at few wavelengths and can deliver low optical energy (normally in the order of μJ), while diode laser bars (DLBs) offer more wavelengths in the market and can deliver more optical energy. We show the simulations of optical systems for beam coupling of single high-power DLBs operating at different wavelengths (i.e. 808 nm, 880 nm, 910 nm, 940 nm, and 980 nm) into 400-μm optical fibers. Then, in a separate design, the beams of the DLBs are combined in a compact system making use of dichroic mirrors and focusing lenses for beam coupling into a 400-μm optical fiber. The use of optical fibers with small core diameter (< 1 mm) is particularly suggestive for future photoacoustic endoscopy (PAE) applications that require interior examination of the body.
One of the main issues of the advances in optoacoustic (OA) applications is to reduce the high costs and the big sizes of solid state lasers. High-power diode lasers (HPDLs) have been demonstrated to be a valid alternative reducing enormously the expenses, besides other advantages such as smaller sizes and higher modulation frequencies. However, in some cases it is possible to furtherly reduce their costs. We present a cost-effective OA system based on the combination of several 905-nm HPDLs with direct coupling into a fiber bundle. These HPDLs have an internal pulse driver, based on an n-channel Mosfet and two charging capacitors, which needs an external Mosfet driver circuit and a voltage supply in order to improve the optical pulse shape and energy. We compare the performances and the prices of this OA system with another similar HPDL-based OA system built with commercial elements. Results indicate good OA signal generation (~15.6 mVpp) with pulse energy of 12.3 μJ and, especially, a cost reduction by a factor of ~15 if compared to the other HPDL-based system.
In the last few decades, high power diode lasers (HPDL) have been introduced as alternative laser sources for optoacoustic imaging (OAI), due to their high repetition rates (a few kHz) for fast OA image acquisition, lower cost and size if compared to solid state lasers. Nevertheless, their drawbacks consist in a low energy per pulse (μJ) and a relatively highly divergent beam that needs collimation optics. At this purpose, the employment of diode laser stacks significantly increases the energy per pulse up to several mJ. The diode laser stacks imply a big challenge if compared to single emitters for several reasons. Firstly, they need very demanding electronic requirements, as forward voltages and currents of several tens of volts and hundreds of amperes, respectively. Secondly, their highly divergent beam profile requires precise collimation by means of fast axis and slow axis collimation. In this work, we show an 808-nm diode laser stack driven with 17 V and ~ 200 A by a low-cost current driver for emitting pulses of 1 mJ at 1 kHz. Particular emphasis will be attributed to the design of the high current pulses driver and the optics employed to collimate and after focus the beam in a spot. The light spot will be applied to an ink inclusion hosted in turbid phantom. We demonstrate that our system is able to generate appreciable OA signals in turbid phantoms. This aspect represents a novelty in OAI systems because it is demonstrated that HPDL sources can efficiently replace solid-state lasers.
Optoacoustic (OA) effect refers to the generation of the acoustic waves due to absorption of light energy in a biological tissue. The incident laser pulse is absorbed by the tissue, resulting in the generation of ultrasound that is typically detected by a piezoelectric detector. Compared to other techniques, the advantage of OA imaging (OAI) technique consists in combining the high resolution of ultrasound technique with the high contrast of optical imaging. Generally, Nd:YAG and OPO systems are used for the generation of OA waves but their use in clinical environment is limited for many aspects. On the other hand, high-power diode lasers (HPDLs) emerge as potential alternative. However, the power of HPDLs is still relatively low compared to solid-state lasers. We show a side-by-side combination of several HPDLs in an optical fiber bundle to increase the amount of power for OA applications. Initially, we combine the output optical power of several HPDLs at 905 nm using two 7 to 1 round optical fiber bundles featuring a 675 μm and 1.2 mm bundle aperture. In a second step, we couple the output light of these fiber bundles to a 600 μm core diameter endoscopic fiber, reporting the corresponding coupling efficiencies. The fiber bundles with reasonable small diameter are likely to be used for providing sufficient light energy to potential OA endoscopy (OAE) applications.
This paper, originally published on 27 April 2016, was replaced with a corrected/revised version on 8 June 2016. If you downloaded the original PDF but are unable to access the revision, please contact SPIE Digital Library Customer Service for assistance.
The purpose of wavelength-beam combining (WBC) is to improve the output power of a multi-wavelength laser system while maintaining the quality of the combined beam. This technique has been primarily proposed for industrial applications, such as metal cutting and soldering, which require optical peak power between kilowatts and megawatts. In order to replace the bulkier solid-state lasers, we propose to use the WBC technique for photoacoustic (PA) applications, where a multi-wavelength focused beam with optical peak power between hundreds of watts up to several kilowatts is necessary to penetrate deeply into biological tissues. In this work we present an analytical study about the coupling of light beams emitted by diode laser bars at 808 nm, 880 nm, 910 nm, 940 nm, and 980 nm into a < 600-μm core-diameter optical fiber for PA endoscopy. In order to achieve an efficient coupling it is necessary to collimate the beams in both fast and slow axes by means of cylindrical lenses and to use partial reflection mirrors at 45° tilt. We show an example of beam collimation using cylindrical lenses in both fast and slow axes. In a real PA scenario, the resulting beam should have a sufficient peak power to generate significant PA signals from a turbid tissue>.
KEYWORDS: Optical fibers, Absorption, Chromophores, Near infrared, High power lasers, Graphene, High power diode lasers, Optical phantoms, Photoacoustic spectroscopy, Tissues, Scattering, Light scattering, Biomedical optics, Signal detection
During the last two decades, optoacoustic imaging has been developed as a novel biomedical imaging technique based on the generation of ultrasound waves by means of laser light. In this work, we investigate the optoacoustic response from graphene-based solutions by using a compact and cost-effective system based on an assembly of several 905-nm pulsed high-power diode lasers coupled to a bundle of 200-μm diameter- core optical fibers. The coupled light is conveyed into a lens system and focused on an absorber consisting of graphene-based nanomaterials (graphene oxide, reduced graphene oxide, and reduced graphene-oxide/gold-nanoparticle hybrid, respectively) diluted in ethanol and hosted in slightly scattering optical phantoms. The high absorption of these graphene-based solutions suggests their potential future use in optoacoustic applications as contrast agents.
Optoacoustic imaging (OAI) is a hybrid biomedical imaging modality based on the generation and detection of ultrasound by illuminating the target tissue by laser light. Typically, laser light in visible or near infrared spectrum is used as an excitation source. OAI is based on the implementation of image reconstruction algorithms using the spatial distribution of optical absorption in tissues. In this work, we apply a time-domain back-projection (BP) reconstruction algorithm and a wavelet filtering for point and line detection, respectively. A comparative study between point detection and integrated line detection has been carried out by evaluating their effects on the image reconstructed. Our results demonstrate that the back-projection algorithm proposed is efficient for reconstructing high-resolution images of absorbing spheres embedded in a non-absorbing medium when it is combined with the wavelet filtering.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.