Paper
5 June 2024 Analysis of fracture failures and structural improvement of a launcher frame
Le Fan, Fuyuan Li, Junjie Niu, Xiaowang Jiang
Author Affiliations +
Proceedings Volume 13163, Fourth International Conference on Mechanical, Electronics, and Electrical and Automation Control (METMS 2024); 131631F (2024) https://doi.org/10.1117/12.3030243
Event: International Conference on Mechanical, Electronics, and Electrical and Automation Control (METMS 2024), 2024, Xi'an, China
Abstract
Aiming at the fracture failures of a launcher frame in the vibration test, the failure cause analysis and structural improvement were carried out. The finite element software Abaqus and the fatigue life analysis software Fe-safe are used for joint simulation to obtain the stress distribution and fatigue life of the launcher frame under the vibration load. The simulation results show several obvious stress concentration phenomenons at the fracture position of the structure, and the fatigue fracture position is consistent with the vibration test. After structural improvement, the fatigue life of the launcher has been increased by 18.6 times, and the overall fatigue life meets the expected usage requirements.
(2024) Published by SPIE. Downloading of the abstract is permitted for personal use only.
Le Fan, Fuyuan Li, Junjie Niu, and Xiaowang Jiang "Analysis of fracture failures and structural improvement of a launcher frame", Proc. SPIE 13163, Fourth International Conference on Mechanical, Electronics, and Electrical and Automation Control (METMS 2024), 131631F (5 June 2024); https://doi.org/10.1117/12.3030243
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Material fatigue

Vibration

Failure analysis

Finite element methods

Safety

Elastic modulus

Structural materials

Back to Top