This study presents an exploratory approach to performing optical coherence tomographic angiography (OCTA) using motion contrast between repeated volumetric scans captured at 200 ms intervals, as opposed to conventional OCTA which measure motion contrast between repeat B-scans captured at shorter intervals. The proposed inter-volumetric OCTA (IV-OCTA) is made possible through an advanced image registration algorithm based on Mattes mutual information metric, and it is implemented on an ultra-high-resolution spectral domain 840 nm OCT system with a 250 KHz A-scan rate. IV-OCTA demonstrates a high detection sensitivity for microvessels with slow blood flow and reduces bulk motion artifacts using the embedded volume registration algorithm. Meanwhile, averaging repeated volumes can substantially reduce the speckle noise for clearer structural imaging compared to the averaged repeated B-scans.
In this study we present a desktop swept-source optical coherence tomographic angiography (OCTA) system for a diverse range of ophthalmic applications. The system can achieve 500 kHz ultrafast imaging with a 75-degree field of view, assisted by a GPU-accelerated real-time cross-sectional and en face OCT/OCTA acquisition interface, a self-tracking method for motion correction, and an AI-based retinal layer segmentation algorithm. High-resolution and high-sensitivity OCTA images from different retinal disease types are demonstrated.
In this study, we developed voxel-wise projection-resolved optical coherence tomographic angiography (PR-OCTA) using artificial intelligence (AI). Two different artificial intelligence models were developed, including a pure convolutional neural network (CNN) model and a CNN and recurrent neural network (RNN) hybrid model. Compared with the state-of-art rules-based model, the AI models were able to preserve more in-situ blood flow and suppress projection artifacts and background noise.
In this study, we present the development of sensorless adaptive optics swept-source optical coherence tomographic angiography (sAO-SS-OCTA) imaging system for mice. GPU-based real-time OCTA image acquisition and processing software was applied to guide wavefront correction using a deformable mirror. High-resolution OCTA images with high capillary resolution and contrast have been successfully acquired. 45-degree field of view high-resolution montaged OCTA image was also acquired.
Detecting and quantifying choroidal neovascularization (CNV) is essential for the diagnosis of neovascular age-related macular degeneration (AMD). Projection-resolved OCT angiography (PR-OCTA) has enabled both en face and volumetric visualization of CNV. However, previously described CNV detection methods only quantify CNV that was already diagnosed, and were unable to identify CNV form unknown inputs . Previous methods were also limited by artifacts. A fully automated CNV diagnosis and quantification algorithm using convolutional neural networks (CNNs) was developed. It was able to diagnose CNV and output CNV membrane and vessel area from retinal structural and angiographic images.
In this study, we demonstrate a novel self-tracking method to suppress eye motions on wide-field optical coherence tomography angiography (OCTA) with a high scanning efficiency. GPU-based real-time OCTA image acquisition and processing software was developed to calculate the eye motion artifacts. An instantaneous motion index was introduced to evaluate the strength of motion artifact on en face OCTA images. Areas with suprathreshold motion and eye blinking artifacts can be rescanned in real-time.
Elevated intraocular pressure (IOP) is an important risk factor for glaucoma. However, the role of IOP in glaucoma progression, as well as retinal physiology in general, remains incompletely understood. We demonstrate the use of visible light optical coherence tomography to measure retinal responses to acute IOP elevation in Brown Norway rats. We monitored retinal responses in reflectivity, angiography, blood flow, oxygen saturation (sO2), and oxygen metabolism over a range of IOP from 10 to 100 mmHg. As IOP was elevated, nerve fiber layer reflectivity was found to decrease. Vascular perfusion in the three retinal capillary plexuses remained steady until IOP exceeded 70 mmHg and arterial flow was noted to reverse periodically at high IOPs. However, a significant drop in total retinal blood flow was observed first at 40 mmHg. As IOP increased, the venous sO2 demonstrated a gradual decrease despite steady arterial sO2, which is consistent with increased arterial-venous oxygen extraction across the retinal capillary beds. Calculated total retinal oxygen metabolism was steady, reflecting balanced responses of blood flow and oxygen extraction, until IOP exceeded 40 mmHg, and fell to 0 at 70 and 80 mmHg. Above this, measurements were unattainable. All measurements reverted to baseline when the IOP was returned to 10 mmHg, indicating good recovery following acute pressure challenge. These results demonstrate the ability of this system to monitor retinal oxygen metabolism noninvasively and how it can help us understand retinal responses to elevated IOP.
Phase wrapping is a crucial issue in Doppler optical coherence tomography (OCT) and restricts its automatic implementation for clinical applications that quantify total retinal blood flow. We propose an automated phase-unwrapping technique that takes advantage of the parabolic profile of blood flow velocity in vessels. Instead of inspecting the phase shift manually, the algorithm calculates the gradient magnitude of the phase shift on the cross-sectional image and automatically detects the presence of phase wrapping. The voxels affected by phase wrapping are corrected according to the determined flow direction adjacent to the vessel walls. We validated this technique in the rodent retina using a prototype visible-light OCT and in the human retina with a commercial infrared OCT system. We believe this signal processing method may well accelerate clinical applications of Doppler OCT in ophthalmology.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please